INSTRUCTION MANUAL
ACD-10 PRO & TRMS PRO
AMPROBE
®
Przeglądanie stron 0
1 2 3 4 5 6 ... 15 16

Podsumowanie treści

Strona 1 - ACD-10 PRO & TRMS PRO

INSTRUCTION MANUAL ACD-10 PRO & TRMS PRO AMPROBE ®

Strona 2

9 ACA Current clamp-on function Inputs are made through the jaws clamps for non-invasive ACA current measurements. CAUTION Press the jaw trigger an

Strona 3

10HOLD The hold feature freezes the display for later viewing. Press the HOLD button momentarily to activate or exit this feature. MAX The max fea

Strona 4

11Trouble Shooting If the instrument fails to operate, check batteries and test leads etc., and replace as necessary. Double check operating procedur

Strona 5

12Sensing : Average sensing for ACD-10 PRO. True RMS for ACD-10TRMS PRO Safety : Meets IEC61010-2-032 (1994), EN61010-2-032 (1995), UL3111-2-032 (199

Strona 6

13DC Voltage: ACD-10 PRO/TRMS PRO RANGE Accuracy 400.0mV 0.3% + 4d 4.000V, 40.00V, 400.0V 0.5% + 3d 600V 1.0% + 4d NMRR : >50dB @ 50/60Hz CMRR

Strona 8

LIMITED WARRANTY Your AMPROBE instrument has a limited warranty against defective materials and/or workmanship for one year from the date of purchase

Strona 9

1Congratulations! You are now the owner of an AMPROBE Instrument. It has been quality crafted according to quality standards and contains quality com

Strona 10

2TERMS IN THIS MANUAL WARNING identifies conditions and actions that could result in serious injury or even death to the user. CAUTION identifies

Strona 11

3INTERNATIONAL ELECTRICAL SYMBOLS Caution ! Refer to the explanation in this Manual Caution ! Risk of electric shock Earth (Ground) Double Ins

Strona 12

43) PRODUCT DESCRIPTION This user's manual uses only representative model(s) for illustrations. Please refer specification details for function

Strona 13

54) OPERATION DC Voltage, AC Voltage, Hz Frequency functions Inputs are made through the test leads terminals. Slide-switch on defaults at DC vol

Strona 14

6Note: DC 400.0mV range is designed with 1000MΩ high input impedance for least current drain in measuring small signals, and can cope better with mos

Strona 15

7 CAUTION Measuring Resistance, Continuity, Diode or Capacitance function on a live circuit will produce false results and may damage the instru

Strona 16

8Ω Resistance, and Continuity functions Inputs are made through the test leads terminals. Slide-switch on defaults at Ω. Press SELECT button momenta