SERVICE
If the instrument fails to operate, check battery, test leads, etc and
replace as necessary. If the instrument still malfunctions, please call
the phone number listed below:
Service Division
AMPROBE INSTRUMENT
Miami, Florida 33150
Tel: 800-327-5060
outside the U.S.A. the local Amprobe representative will assist you.
Visit our Web-site HTTP://www.AMPROBE.COM
|
AMPROBE
®
DIVISION OF CORE INDUSTRIES INC.
Miami, Florida 33150
Tel: 800-327-5060
Przeglądanie stron 0
1 2 3 4 5 6 ... 64 65

Podsumowanie treści

Strona 1 - Tel: 800-327-5060

SERVICEIf the instrument fails to operate, check battery, test leads, etc andreplace as necessary. If the instrument still malfunctions, please callth

Strona 2 - CLAMP-ON MULTIMETER

USING THE METER SAFELYcWARNINGRead " SAFETYINFORMATION" before using the meter..cNOTE Some typical tests are provided in this manual. These

Strona 3 - AMPROBE INSTRUMENT

LCD DISPLAYILLUSTRATION 1) - Negative polarity Annunciator2) @OFF Auto Power Off Enabled Annunciator3)q Low Battery Annunciator4) DC Direct Current or

Strona 4 - CONTENTS

11Figure 2. LCD Display

Strona 5 - CONTENTS continued

12Figur3 3. Alignment MarksIn order to meet the meeter accuracy spacifications when making a current meas-urement, the conductor must be inside the ja

Strona 6

Rotary SwitchTo turn the meter on and select a function, turn the rotary switch(Figure 4) to a switch setting. The whole display lights for one second

Strona 7

INPUT TERMINALWARNINGTo avoid damaging the meter, do not exceed input limit shown belowTable 1:Table 1. Input limit specificationTable 1. The meter ha

Strona 8

Figure 6. Push bottons151. Press to lselectDC.AC,DC+ACPress and hold formore than 1 second to toggle, betweenPEAK" and DC.Press to toggle

Strona 9

16Push-button OperationsThe operation of the push-buttons are outlined below. When a buton is pushed,an annunciator lights, and the unit beeps. turnin

Strona 10

174. Zero ❍:● Push this button momentarily to zero the residual current. Note: Allow themeter to stabilize before zeroing the display. The &q

Strona 11 - IIIIIIIIIl4

POWER-ON OPTIONScSELECTING POWER-ON OPTIONSSome options can only be selected when you turn the meter on. These power-onoptions are listed in Table 2.T

Strona 12 - Figure 2. LCD Display

USER MANUALMODEL: ACDC-620T|AMPROBE®Miramar, Florida 33025Tel: 800-327-5060AUNIQUE AC / DC TRUE RMSCLAMP-ON MULTIMETERUL®CLISTEDManual P/N: 9787608/9

Strona 13

SPECIALFUNCTIONS INSTRUCTIONSThis clamp-on multimeter provides the operator with various functions including:cDynamic RecordingcData HoldcZero (Relati

Strona 14

3. The beeper sounds when a new maximun or minimum value is recorded.4. If an overload is recorded the averaging function is stopped. An average value

Strona 15 - Ω - µF & COM

Figure 7. Display of Dynamic Recording211. Press for more than 1 second to enter Dynamic Recording

Strona 16 - Figure 6. Push bottons

cDATAHOLDThe data HOLD function allos operator to freeze the displayed digital value whilethe aanlog bargraph displays present readings. Press "

Strona 17 - Ω and Temperature

cANALOGBATRGRAPHThe analog bargraph display provides a 12-segment analog reading representa tion. The unit of the bargraph is 100 counts/bar.Figure 9.

Strona 18 - ))"

Figura 10. Analog Bar graphcAUTO POWER OFFAND SLEEPMODEThere are two modes for power saving.1 ) The instrument will enter the "sleep" mode w

Strona 19 - SELECTING POWER-ON OPTIONS

25cDISABLE AUTO POWEROFFWhen the meter is to be used for long periods of time you may want to disable theauto power off. Once the auto power off funct

Strona 20

cCONTINUITY FUNCTION FOR OHMS MEASUREMENTTo enable the continuity function, set the meter to the Ω range. Press ●))) button momentarily to toggle the

Strona 21

c1ms Peak HoldYou can use this Meter to analyze components such as power distribution trans-formers and power factor correction capacitors. The additi

Strona 22

3) If the reading is " OL", then you can push RANGE button momentarily to change measuring range and restart the PEAK+ measurement after set

Strona 23 - ∆ "

1LIMITED WARRANTYCongratulations! You are now the owner of an AMPROBE®instrument. It has beenquality crafted according to quality standards and contai

Strona 24 - ANALOGBATRGRAPH

HOW TO OPERATEcAC CURRENT MEASUREMENTWARNING: MAKE CERTAIN THATALLTESTLEADS ARE DISCONNECTED FROM THE METER TERMINALS.1 ) Set the rotary switch to &

Strona 25

Figure 17. Measuring AC Current.CORRECTINCORRECT30

Strona 26 - ❚ ❚ ❚

cDISTRIBUTION TRANSFORMER MEASUREMENTYou can measure current, phase imbalance between phases, and true RMS neutralcurrent. True RMS measurement yields

Strona 27

Figure 18. Measuring AC Curreft32

Strona 28

cAC MOTOR CURRENT MEASUREMENTYou can measure starting (inrush) current , running current, and current imbal-ance in AC Motor circuits. Inrush current

Strona 29

Figure 19. Measuring AC Motor Curent 34

Strona 30 - HOW TO OPERATE

cAC VOLTAGE MEASUREMENT1. Set the rotary switch to "V".2. Insert the black test lead to "COM" terminal and red test lead to "

Strona 31 - INCORRECT

Figure 20. Measuring Voltage.36

Strona 32

cRESISTANCE / CONTINUITYMEASUREMENTCAUTION: Make sure that power is removed and allcapacitors have been discharged before measuring.1) Set the rotary

Strona 33

Figura 21. Measuring Resistance and Continuity.FUSECARTRIDGE38

Strona 34

2CONTENTSPÁGINALIMITED WARRANTY 1SAFETYINFORMATION 4AUNIQUE CLAMP-ON MULTIMETER 6● INTRODUCTION 6USING THE METER SAFELY 8LCD DISPLAYILLUSTRATION 1

Strona 35

cTEMPERATURE (K-TYPE) MEASUREMENTSThe ACDC-620TLCD contains a dual display forTemperature Measurement. The larger digits display oF (Fahrenheit), and

Strona 36 - Ω - µF" terminal

Figure 22. Surface Temperature Measurement.40PressShift

Strona 37 - Figure 20. Measuring Voltage

●To perform dual input and/or differential temperature measurement:1) Set the rotary switch to "TEMP. Ω ".2) Insert the model DKTA-620 Dual

Strona 38 - Ω - µF " terminal

Figure 23. Measuring Temperature on Refrigeration System.Contact whereyou want to measuringPRESS ∆T42

Strona 39 - CARTRIDGE

cCAPACITANCE MEASUREMENTSIn many instances a motor can not be started due to a failed start/run capacitor. Totest the capacitor:: Discharge the capaci

Strona 40 - Ω "

Figure 24. CAPACITANCEMEASUREMENTS.44Negro (-)Rojo(+)

Strona 41

GENERALSPECIFICATIONSDisplay:Display: Fully annunciated 4-digit liquid crystal display (LCD) with maximum readingof 4,000 count. Dual display in Tempe

Strona 42

MAX. Jaw Opening:To Accommodate Circuit Cables 2" ( 50.8 mm ) diameter.Dimension:32 (H) x 64 (W) x 260 (L) mm1.26"(H) x 2.52"(W) x 10.2

Strona 43 - Contact where

47Accessories and ReplacementsPartsSafety Test Leads(included)Carryimg Case(included)Instruction Manual(included)9 Volt Alkaline Battery(included)Dual

Strona 44

ELECTRICALSPECIFICATIONSAccuracy is giveN as ± % of reading + the number of least significant digits at 23oC ± 5oC, with relative hunidity Less than

Strona 45

CONTENTS continuedPAGEHOW TO OPERATE●AC CURRENTMEASUREMENT 29●DISTRIBUTION TRANSFORMER MEASUREMENT 29●AC MOTOR CURRENTMEASUREMENT 31●AC VOLTAGE MEASUR

Strona 46 - Display:

49Range Resolution Accuracy400A 0.1A1000A 1A±(1,5%rdg+3rdg)±(2% rdg+ 5rdg)cDC CURRENTRange Resolution Accuracy400A 0.1A1000A 1A45Hz~65Hz 65Hz~2kHz±(2%

Strona 47

RANG Resolution Accuracy *V Maximum -40°C ~1372°C 1°C-40°F ~ 2502°F 1°F±(0,5%rdg+3°C)±(0,5%rdg+6°F)30 V RMSor 60 V

Strona 48

CURRENT HARMONICS THEORYTrue-RMS current is very important because it directly relates to the amount ofheat dissipated in wiring, transformers, and lo

Strona 49

non-linear current. This generates odd harmonics of the 5OHz or 60Hz linefrequency. Therefore, the current waveform from the transformer could contain

Strona 50

53cTRUERMSMEASUREMENTThe meter measures the TRUERMS value of AC voltages and currents. In physicalterms, the RMS (Root-Mean-Square) value of a wavefor

Strona 51

cWAVEFORMCOMPARISONTa b l e3. Illustrates the relationship between AC and DC components for commonwaveforms, and compares readings for TRUE RMS mete

Strona 52

Table 3. WAVEFORMCOMPARISONCHART55* RMS CALIS THE DISPLAYED VALUEFOR AVERAGE RESPONDING METERSTHATARE CALIBRATED RMS FOR SINE WAVES.

Strona 53

56REFRIGERATIN THEORYThermocouples are widely used in the process control and refrigeration industry. Areview of basic refrigeration theory will help

Strona 54

57cThe Refrigation CycleInside a refrigerator, a compressed gas in liquid form is released through an expan-sion valve into the low pressure of an eva

Strona 55

Once outside, the gas enters the compressor on the low-pressure side and iscompressed. As it is compressed, the gas temperature rises above the surrou

Strona 56

4SAFETYINFORMATIONcSAFETYINFORMATION:●To ensure that you use meter safely, follow the safety guidelines listed below.●This meter is for indoor use, al

Strona 57 - REFRIGERATIN THEORY

59Condenser TemperatureThe condenser's entire mid-section should be at the refrigerant's condensing tem-perature. The condensing temperature

Strona 58 - THERMOSTATICEXPANSION VALVE

Condenser Sub-coolLike the evaporator, the condenser is sized so that all the gas will be condensedbefore the last few coils, the liquid temperature d

Strona 59

61MAINTENANCEWARNINGTo avoid electrical shock, do not perform any servicing unless you are qualified todo so.cSERVICEIf the instrument fails to operat

Strona 60

62Figure 26. step 1 of Battery replacement.Pull up slightly

Strona 61 - Condenser Sub-cool

63Figure 27. Step 2 of Battery Replacement.Pull and move to right.

Strona 62

64c CLEANINGTo clean the instrument, use s soft cloth dampened in a solution of mild detergentand water. Do not spery cleaner directly onto the instru

Strona 63 - Pull up slightly

●Set the proper function and renge before attaching the metr to circuit. To avoid damaging the meter disconnect the test leads from test points befor

Strona 64 - Pull and move to right

6AUNIQUE CLAMP-ON MULTIMETERcINTRODUCTIONMeasuring current accurately is difficult job in today's industrial plants and com-mercial buildings.An

Strona 65

Figure 1. AUnique Clamp-On Multimeter7Start capacitormeasurementOhm measurement andk-type temperatureVoltage measurementCurrent measurement1ms Peak Ho