Amprobe ACDC-100 TRMS Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Pomiary, testowanie i kontrola Amprobe ACDC-100 TRMS. Amprobe ACDC-100 TRMS User`s manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 14
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
USER'S
MANUAL
ACDC-100 TRMS
ACDC-100
Versatile AC/DC
Clamp-on Multimeter
Series
99 Washington Street
Melrose, MA 02176
Fax 781-665-0780
TestEquipmentDepot.com
Przeglądanie stron 0
1 2 3 4 5 6 ... 13 14

Podsumowanie treści

Strona 1 - USER'S

USER'S MANUAL ACDC-100 TRMS ACDC-100 Versatile AC/DC Clamp-on Multimeter Series 99 Washington Street Melrose, MA 02176

Strona 2

9Battery replacement The meter uses standard 1.5V AAA Size (NEDA 24G or IEC R03) battery X 2; or 1.5V AAA Size (NEDA 24A or IEC LR03) alkaline batter

Strona 3

106) SPECIFICATIONS General Specifications Display : 3-3/4 digits 4000 counts LCD display(s) Update Rate : 3 per second nominal Polarity : Automatic

Strona 4

11Electrical Specifications Accuracy is ±(% reading digits + number of digits) or otherwise specified, at 23oC ± 5oC & less than 75% R.H. ACDC

Strona 5

12Ohms RANGE Accuracy 400.0Ω 0.8% + 6d 4.000kΩ, 40.00kΩ, 400.0kΩ 0.6% + 4d 4.000MΩ 1.0% + 4d 40.00MΩ 2.0% + 4d Open Circuit Voltage : 0.4VDC typical

Strona 6

13ACA Current (Clamp-on) RANGE Accuracy1) 2) 400.0A 15Hz ~ 40Hz 2.0% + 5d 3) 40Hz ~ 200Hz 1.5% + 5d 200Hz ~ 400Hz @ <50A 4) 1.5% + 5d 400Hz ~ 1

Strona 7

11) SAFETY This manual contains information and warnings that must be followed for operating the instrument safely and maintaining the instrument in

Strona 8

2WARNING To reduce the risk of fire or electric shock, do not expose this product to rain or moisture. The meter is intended only for indoor use. T

Strona 9

33) PRODUCT DESCRIPTION This user's manual uses only representative model(s) for illustrations. Please refer specification details for function

Strona 10

44) OPERATION DC Voltage and AC Voltage functions Inputs are made through the test lead terminals. Note: DC 400.0mV range is designed with 1000MΩ

Strona 11

5 ACA & DCA Current clamp-on function Inputs are made through the clamp jaws for non-invasive ACA & DCA current measurements. CAUTION (App

Strona 12

6 CAUTION Using Resistance, Continuity or Diode function in a live circuit will produce false results and may damage the instrument. In many cases t

Strona 13

7 Capacitance function Inputs are made through the test leads terminals. Slide-switch on defaults at Ω. Press SELECT button momentarily 3 times to se

Strona 14

8Display Backlight (ACDC-100 TRMS only) Press the SELECT button for 1 second or more to toggle the display backlight on and off. Auto Power Off (APO